Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Rev Esp Enferm Dig ; 114(7): 427-428, 2022 07.
Article in English | MEDLINE | ID: covidwho-1675360

ABSTRACT

We would like to comment on the publication "Uncommon causes of acute appendicitis: foreign bodies in the cecal appendix." Rodríguez Lucas et al. presented a COVID-19 recipient who presented with acute appendicitis and surgical exploration detected dental prosthesis. The foreign body might be the cause of acute appendicitis. Dental protsthesis is a possible problematic foreign body that might be trapped in appendix. The history of dental prosthesis loss might be a useful clue for this specific clinical situation.


Subject(s)
Appendicitis , COVID-19 , Dental Prosthesis , Foreign Bodies , Acute Disease , Appendicitis/etiology , Appendicitis/surgery , Appendix , COVID-19/prevention & control , COVID-19 Vaccines , Foreign Bodies/complications , Foreign Bodies/diagnostic imaging , Foreign Bodies/surgery , Humans , Vaccination
2.
Rev Esp Enferm Dig ; 114(6): 361-362, 2022 06.
Article in English | MEDLINE | ID: covidwho-1662906

ABSTRACT

A 50-year-old woman with a history of hysterectomy for endometrial cancer in 2015 visited because of abdominal pain for 1 week and fever simultaneous with her third dose of the COVID-19 vaccine. Physical examination revealed a mobile mass in the right iliac fossa, and laboratory testing showed C-reactive protein at 3 mg/dL, with no further changes. Ultrasound results were consistent with an appendiceal inflammatory mass, and a CT scan revealed an appendicolith as likely cause. The patient was subjected to laparoscopy, which found inside the mass a metallic piece (dental prosthesis) that perforated the appendiceal lumen at the mid portion of the appendix. Appendectomy was completed and the patient was discharged on the third day post-procedure.


Subject(s)
Appendicitis , Appendix , COVID-19 , Foreign Bodies , Acute Disease , Appendectomy , Appendicitis/diagnostic imaging , Appendicitis/etiology , Appendicitis/surgery , Appendix/diagnostic imaging , Appendix/surgery , COVID-19 Vaccines , Female , Foreign Bodies/complications , Foreign Bodies/diagnostic imaging , Foreign Bodies/surgery , Humans , Middle Aged
3.
BMC Surg ; 22(1): 6, 2022 Jan 08.
Article in English | MEDLINE | ID: covidwho-1639167

ABSTRACT

BACKGROUND: Ingestion of fish bones leading to gastric perforation and inducing abscess formation in the caudate lobe of the liver is very rare. CASE PRESENTATION: A 67-year-old man presented to our hospital with a 2-day history of subxiphoid pain. There were no specific symptoms other than pain. Laboratory tests showed only an increase in the number and percentage of neutrophils. Contrast-enhanced Computerized tomography (CT) of the abdomen showed two linear dense opacities in the gastric cardia, one of which penetrated the stomach and was adjacent to the caudate lobe of the liver, with inflammatory changes in the caudate lobe. We finally diagnosed his condition as a caudate lobe abscess secondary to intestinal perforation caused by a fishbone based on the history and imaging findings. The patient underwent 3D laparoscopic partial caudate lobectomy, incision and drainage of the liver abscess, and fishbone removal. The procedure was successful and we removed the fishbone from the liver. The patient was discharged on the 9th postoperative day without other complications. CONCLUSIONS: Liver abscess caused by foreign bodies requires multidisciplinary treatment. Especially when located in the caudate lobe, we must detect and remove the cause of the abscess as early as possible. Foreign bodies that perforate the gastrointestinal tract can penetrate to the liver and cause abscess formation, as in this case. When exploring the etiology of liver abscesses, we should investigate the general condition, including the whole gastrointestinal tract.


Subject(s)
Foreign Bodies , Foreign-Body Migration , Laparoscopy , Liver Abscess , Aged , Animals , Foreign Bodies/complications , Foreign Bodies/diagnostic imaging , Foreign Bodies/surgery , Foreign-Body Migration/complications , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/surgery , Humans , Liver Abscess/diagnostic imaging , Liver Abscess/etiology , Liver Abscess/surgery , Male
4.
Monaldi Arch Chest Dis ; 92(3)2021 Dec 03.
Article in English | MEDLINE | ID: covidwho-1555780

ABSTRACT

The COVID-19 pandemic has resulted in a significant increase in the number of tracheostomised patients in hospitals requiring ventilatory support. These patients require highly specialist care, but overwhelmed hospital systems with stretched human resources potentially leave these patients cared for by undertrained healthcare professionals. We describe a rare complication where a routine COVID-19 swab done incorrectly via a tracheostomy tube, resulted in a snapped-off swab in the trachea. We outline the events and our method of removal using rigid bronchoscopy through the tracheostomy stoma as endo-tracheal bronchoscopy was impossible due to significant sub-glottic stenosis. This case highlights the paramount importance of the unique care needed to safely manage tracheostomies during this ongoing pandemic.


Subject(s)
COVID-19 , Foreign Bodies , Bronchoscopy , Foreign Bodies/diagnosis , Foreign Bodies/diagnostic imaging , Humans , Pandemics , Trachea/diagnostic imaging , Tracheostomy
6.
BMJ Paediatr Open ; 5(1): e001042, 2021.
Article in English | MEDLINE | ID: covidwho-1476623

ABSTRACT

Introduction: During the COVID-19 pandemic in 2020, there were many changes in the provision of healthcare as well as home and educational environments for children. We noted an apparent increase in the number of children presenting with ingested foreign bodies and due to the potential impact of injury from this, further investigated this phenomenon. Method: Using a prospective electronic record, data were retrospectively collected for patients referred to our institution with foreign body ingestion from March 2020 to September 2020 and compared with the same period the year prior as a control. Results: During the 6-month pandemic period of review, it was observed that 2.5 times more children were referred with foreign body ingestion (n=25) in comparison to the control period (n=10). There was also a significant increase in the proportion of button battery and magnet ingestions during the COVID-19 pandemic (p 0.04). Conclusion: These findings raise concerns of both increased frequency of foreign body ingestion during the COVID-19 pandemic and the nature of ingested foreign bodies linked with significant morbidity. This may relate to the disruption of home and work environments and carries implications for ongoing restrictions. Further awareness of the danger of foreign body ingestion, especially batteries and magnets, is necessary (project ID: 2956).


Subject(s)
COVID-19 , Foreign Bodies , Child , Eating , Foreign Bodies/diagnostic imaging , Humans , Pandemics , Prospective Studies , Retrospective Studies , SARS-CoV-2
8.
J Med Case Rep ; 15(1): 291, 2021 May 22.
Article in English | MEDLINE | ID: covidwho-1238732

ABSTRACT

BACKGROUND: Bronchobiliary fistula is an extremely rare disease that involves abnormal communication between a hepatic segment and bronchial tree. It is mostly caused by untreated hydatid cyst, liver abscess, iatrogenic stenosis, and, rarely, trauma. CASE PRESENTATION: We experienced an extremely rare case of bronchobiliary fistula after motor vehicle accident. A 15-year-old Persian boy visited our clinic with chief complaints of persistent pleuritic chest pain, productive cough, weight loss, and fever for 2 months. Coronavirus disease 2019 reverse transcription polymerase chain reaction test was negative. Chest X-ray revealed hazy opacification of right lower lobe. Bronchoalveolar lavage for acid-fast bacillus came back negative. Thoracoabdominal computed tomography scan revealed a collection in segment VIII of the liver communicating with another 13 × 5 cm multiloculated collection in the lower lobe of the right lung, with air foci within the collection. Right posterolateral thoracotomy was performed with the impression of bronchobiliary fistula. Drainage of hepatic collection with debridement, diaphragmatic repair, and open decortication of lung followed by resection of the involved segment of the right lung was performed. Histopathologic evaluations revealed abscess formation in pulmonary tissue, and many multinucleated giant cells were seen that appear to be due to foreign body remnants after previous laparotomy surgery. The foreign body seemed to be the remnants of Surgicel absorbable hemostat. CONCLUSIONS: Herein, we report an extremely rare case of a posttraumatic bronchobiliary fistula caused by remnants of Surgicel hemostatic agent. Bronchobiliary fistula is mainly caused by untreated hydatid cyst, liver abscess, iatrogenic stenosis, and, rarely, trauma. Migration and erosion of oxidized regenerated cellulose through the diaphragm seems to be the causative factor of bronchobiliary fistula in this patient.


Subject(s)
Biliary Fistula , Bronchial Fistula , Foreign Bodies , Adolescent , Biliary Fistula/diagnostic imaging , Biliary Fistula/etiology , Biliary Fistula/surgery , Bronchial Fistula/diagnostic imaging , Bronchial Fistula/etiology , Bronchial Fistula/surgery , Foreign Bodies/complications , Foreign Bodies/diagnostic imaging , Foreign Bodies/surgery , Humans , Male
11.
Clin J Gastroenterol ; 14(1): 44-47, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-778111

ABSTRACT

Long and sharp objects can be foreign body intentionally or accidentally ingested. Timing of endoscopy relies on foreign body shape and size, localization in gastrointestinal tract, patient's clinical conditions, occurrence of symptoms, or onset of complications. We present a case of a 47-year-old male with no known comorbidity, who accidentally swallowed a portion of a naso-pharyngeal swab half-broken during the second diagnostic test for SARS-CoV-2. The intact swab had a total length of 15 cm and was made of wood. The patient was asymptomatic, laboratory tests were normal, and neck-chest-abdominal X-ray and CT scan were negative for major complications. Upper gastrointestinal endoscopy was promptly performed to prevent the long sharp swab from crossing the pylorus leading to serious complications and, therefore, risk surgical intervention. The patient was intubated and the procedure was carried out under general anesthesia. In the gastric body, broken naso-pharyngeal swab was detected among the food debris, and using a latex rubber hood, the 7.5 cm foreign body was removed with a retrieval alligator-tooth forceps. Our hospital is located in a high-risk area of COVID-19 outbreak where many naso-pharyngeal swabs are performed, and to our knowledge, this is the first report of swab ingestion during SARS-CoV-2 test.


Subject(s)
COVID-19 Testing , COVID-19 , Foreign Bodies , Gastroscopy/methods , Specimen Handling , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/prevention & control , COVID-19 Testing/instrumentation , COVID-19 Testing/methods , Deglutition , Diagnostic Equipment/adverse effects , Foreign Bodies/diagnostic imaging , Foreign Bodies/etiology , Foreign Bodies/surgery , Humans , Male , Middle Aged , SARS-CoV-2/isolation & purification , Specimen Handling/adverse effects , Specimen Handling/instrumentation , Specimen Handling/methods , Treatment Outcome
12.
BMJ Case Rep ; 13(8)2020 Aug 27.
Article in English | MEDLINE | ID: covidwho-733174

ABSTRACT

We report the case of a bronchial foreign body, following a tracheostomy site swab for SARS-CoV-2, aiming to raise awareness and vigilance. A qualified nurse was performing a routine SARS-CoV-2 swab on a 51-year-old woman, fitted with a tracheostomy in the recent past following a craniotomy. This was part of the discharging protocol to a nursing home. During the sampling, part of the swab stylet snapped and was inadvertently dropped through the tracheostomy site. Initial CT imaging was reported as showing no signs of a foreign body but some inflammatory changes. Bedside flexible endoscopy through the tracheostomy site revealed the swab in a right lobar bronchus. This was subsequently removed by flexible bronchoscopy. This case highlights the need for clear guidance on how samples for SARS-CoV-2 are taken from patients with front of neck airways (laryngectomy/tracheοstomy) and the potential pitfalls involved.


Subject(s)
Bronchi/diagnostic imaging , Coronavirus Infections/diagnosis , Foreign Bodies/diagnostic imaging , Pneumonia, Viral/diagnosis , Specimen Handling/instrumentation , Tracheostomy , Betacoronavirus , Bronchi/surgery , Bronchoscopy , COVID-19 , COVID-19 Testing , Clinical Laboratory Techniques , Female , Foreign Bodies/surgery , Humans , Middle Aged , Pandemics , SARS-CoV-2 , Specimen Handling/adverse effects , Tomography, X-Ray Computed
13.
Skeletal Radiol ; 49(11): 1873-1877, 2020 Nov.
Article in English | MEDLINE | ID: covidwho-723995

ABSTRACT

The ongoing coronavirus disease 2019 (COVID-19) pandemic has increased the need for safe and efficient testing as a key containment strategy. Drive-through testing with nasopharyngeal swab has been implemented in many places in the USA as it allows for expeditious testing of large numbers of patients, limits healthcare workers' risk of exposure, and minimizes the use of personal protective equipment. We present a case where the aluminum shaft of the nasopharyngeal swab fractured during specimen collection at a drive-through testing facility and was suspected to have remained in the asymptomatic patient. Initial evaluation with a series of radiographs covering the skull base, neck, chest, and abdomen did not reveal the swab. On further clinical evaluation, the swab was found endoscopically, lodged between the left inferior turbinate and nasal floor, and was removed by an otorhinolaryngologist. Using a phantom model, we aimed to delineate an imaging technique to better visualize the aluminum shaft of the nasopharyngeal swab on radiographs to help in identification. A technique using lower tube voltage (kVp) with tight collimation centered at the nasal bones area produced the best visualization of the aluminum shaft of the swab. Recognition that aluminum foreign bodies may be difficult to visualize radiographically and  optimization of radiograph acquisition technique may help guide clinical management in unusual cases. Further evaluation with computed tomography or endoscopy should be considered in suspected cases where radiographs are negative.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques/instrumentation , Coronavirus Infections/diagnosis , Equipment Failure , Foreign Bodies/diagnostic imaging , Pneumonia, Viral/diagnosis , Specimen Handling/instrumentation , Aged, 80 and over , Aluminum , COVID-19 , COVID-19 Testing , Humans , Male , Pandemics , Radiography/methods , SARS-CoV-2 , Surgical Instruments
SELECTION OF CITATIONS
SEARCH DETAIL